-7%
Dell EMC Compellent SCv3020H 11×1.92TB SSD 15×2.4TB SAS 8xFC 8xiSCSI DC (SNS3020H)
สอบถามผ่าน LINE ID : @COMVENDOR
เช็คสต็อกสอบถามสินค้า : คุณภาวัช 088-2694142 , 080-4195351
DC 8x iSCSI Base T, 8x16G FC / 3U upto 30 HDD / 11x 1.92TB RI SSD SAS, 2.5″ HDD / 15x 2.4TB, SAS, 12Gb, 10K, 2.5″ HDD / 2x Power Supply, 1,485W, Redundant / ReadyRails II Static Rails for 4-post Racks / No Installation Services Selected / Storage Optimization Bundle, Software License / 3Yr ProSupport Plus and Mission Critical: (7×24) 4-hour Onsite Service
฿1,335,000.00 (ไม่รวมภาษี)
- Description
- Datasheet
- Reviews (0)
- คุณสมบัติเฉพาะ
Description
Dell EMC Compellent SCv3020H 11×1.92TB SSD 15×2.4TB SAS 8xFC 8xiSCSI DC (SNS3020H)
- Dual Controller, 8x iSCSI Base T, 8x16G FC, 3U upto 30 HDD
- 11x 1.92TB RI SSD SAS, 2.5″ HDD
- 15x 2.4TB, SAS, 12Gb, 10K, 2.5″ HDD
- 2 x Power Supply, 1,485W, Redundant
- ReadyRails II Static Rails for 4-post Racks
- No Installation Services Selected
- Storage Optimization Bundle, Software License
- 3 Years ProSupport Plus and Mission Critical: (7×24) 4-hour Onsite Service
Dell EMC Compellent SCv3000 Series Storage Arrays
Our most affordable hybrid arrayNew entry point to SC Series auto-tiering and enterprise-class storage features![]() |
Tech Specs & Customization
Chassis OverviewChassis formatAll-in-one (dual controllers, internal drive bays, networking and expansion ports) Rack size 3U Controllers 2 hot-swappable per chassis (active/active) Processors Intel® Xeon® Processor E5-2603v4, 1.7GHz, 6 cores Internal storage capacity SCv3000: 16 x 3.5” drive bays SCv3020: 30 x 2.5” drive bays System memory 32GB per SCv3xxx array (16GB per controller) Operating system Storage Center OS (SC OS) 7.2 or greaterData Mobility and MigrationReplication Replicates with other SC Series arrays* Synchronous/Asynchronous via FC or iSCSI Per-volume QoS bandwidth prioritization Target/source relationships may be one-to-many or many-to-one Supports all SC data services on source and target volumes Change replication types and topologies on demand Supports cross-platform replication with PS Series/EqualLogic arrays (either direction) Volume mobility Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section Federated multi-array systems Live Migrate (included in base product) enables host-transparent movement of volumes among arrays Snapshots maintained/preserved during migration Thin Import Space-efficient, non-disruptive data migration from PS Series (EqualLogic) arrays Thin Clones Clone standalone volumes with zero duplication of data Clones maintain independent snapshots and replication Ideal for VDI, test/dev, other applications that require discrete instances of common data More efficient than dedupe for database copiesData OptimizationAuto-tiering method Policy-based migration based on real-time data usage, customizable 512KB-4MB page size. Auto-tiering structure Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs) Tiering customizations User-defined profiles, option to “pin” volumes to any tier RAID support RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist on a single array RAID tiering Auto-provisions and dynamically restripes multiple RAID levels on the same tier; no need to pre-allocate RAID groups Thin provisioning Active by default on all volumes, operates at full performance across all features Thin snapshots Records changes only, snapshots auto-migrate to lower-cost storage Intelligent compression Selectable option per volume Applies to SSDs, HDDs or both in hybrid configurations HDD optimization FastTrack moves frequently accessed data to outer tracks for quicker response timesEnvironmental Operating ConditionsOperating temperature: 50 - 95°F (10 - 35°C) Non-operating temperature: -40 - 149°F (-40 - 65°C) Operating humidity ranges (non-condensing): 10% to 80% with 29°C (84.2°F) maximum dew point Non-operating humidity (non-condensing): 5% to 95% with 33°C (91°F) maximum dew point Inlet type: NEMA 5-15/CS22.2, n°42 |
Expansion CapacitySupported expansion enclosures SCv300: 12 x 3.5” drive bays (12Gb SAS) SCv320: 24 x 2.5” drive bays (12Gb SAS) SCv360: 60 x 3.5” drive bays (12Gb SAS)* Maximum drive count 222 per array (internal plus external expansion), more in federated systems* Max raw capacity 1PB per array* (SSD or HDD), more in federated systems Storage media SAS and NL-SAS drives; different drive types, transfer rates and rotational speeds can be mixed in the same system. SSD: write-intensive and read-intensive drives HDD: 15K, 10K, 7.2K RPMFunctionalArray configurations All-flash, hybrid or HDD arrays Storage format Block (SAN)* Max SAN hosts: 250 Max initiator ports: 500 Max LUN size 500TB Max number of LUNs: 1000 Max number of snapshots: 4096 Max IOPS: 665,000* Max IOPS (with latency less than 1ms): 540,000* Max IOPS (80% reads, 20% writes): 231,000* Max throughput (reads): 19,000 MB/s* Max throughput (writes): 9,500 MB/s*ManagementManagement interface Browser-based (HTML 5): Unisphere for SC (element manager) Unisphere Central (multi-array management) CloudIQ (cloud-based analytics and monitoring) Client application: Dell Storage Manager (multi-array, multi-site, cross-platform management) Federation Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection.* Scripting support Microsoft PowerShell API RESTful API Host OS support Microsoft® Windows Server®, Novell® NetWare, SLES, VMware®, Citrix® XenServer®, RedHat® Third-party application integration VMware, Oracle, Microsoft, IBM, OpenStack™, Symantec™, Commvault®, Veeam®, Docker™ -- see SC Series Management spec sheet for more details Coexistence with PS Series arrays Replication in either direction Day-to-day management from a single interface Thin import: space-efficient, non-disruptive data migration from PS Series arrays Certifications VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite; see Dell Storage Support Matrix for additional certifications and details Reporting/alerts Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback Firmware updates Online, non-disruptive.* Firmware may be set to download automatically, with option to trigger installation manually if desired. Workload management QoS, VVOLs |
Network and Expansion I/OFront-end-network protocols FC, iSCSI, SAS (supports simultaneous multiprotocol): FC + iSCSI or SAS + iSCSI) Max 16Gb FC ports 8 per array (SFP+) Max 10Gb iSCSI ports 16 SFP+ or BaseT per array Max 12Gb SAS ports Up to 8 12Gb SAS ports* Management ports 2 per array (1Gb BASE-T) Back-end expansion protocols 12Gb SAS Max back-end expansion ports 8 per array Up to 16 expansion enclosures per arrayPhysicalSCv3000 Rack size: 3U Height: 13.33 cm (5.25 inches) Width: 44.5 cm (17.52 inches) Depth: 78.5 cm (30.9 inches) Weight at maximum configuration: 24.22 kg (53.4 lb) Weight empty: 15.15 kg (33.4 lb) SCv3020 Rack size: 3U Height: 13.33 cm (5.25 inches) Width: 44.5 cm (17.52 inches) Depth: 78.5 cm (30.9 inches) Weight at maximum configuration: 24.22 kg (53.4 lb) Weight empty: 15.15 kg (33.4 lb)PowerPower/wattage: 2 hot-swappable power supplies (1378W or 1485W options available, wattage type not interchangeable after point of sale) Maximum output power: 1378W supply option: 1378 W; 1485W supply option: 1485 W Maximum input power: 1378W supply option: 1584 W; 1485W supply option: 1688 W Maximum input current: 1378W supply option: 16 A, 1485W supply option: 8.8 A Maximum inrush current: 55A for 10 ms or less Nominal input voltage operating range: 1378W supply option: 100-240 VAC; 1485W supply option: 200-240 VAC Nominal input frequency: 50/60 Hz Maximum thermal output/heat dissipation: 1378W option: 5,770 BTU per hour; 1485 option: 5,760 BTU per hour (for all-in-one base appliance, no expansion enclosures)RegulatoryProduct Safety, EMC and Environmental Datasheets Dell Regulatory Compliance Home PageDell and the Environment Data Protection FeaturesBusiness continuity Live Volume bi-directional auto-failover, auto-repair* Continuous operations, disaster recovery, disaster avoidance Includes third-site (tertiary) replication options with Live Volume Managed Replication* Zero RTO/RPO with customizable site failover SLAs per volume VMware Metro Stretch Cluster support VMware Site Recovery Manager Distributed sparing No dedicated hot spares required, all drives available for I/O Thin snapshots Records changes only, snapshots auto-migrate to lower-cost storage Application Consistency Replay Manager: Application-consistent snapshots in Microsoft or VMware environments AppSync: Application-consistent snapshots in Microsoft, VMware, Oracle environments Data-at-rest encryption Self-encrypting drives (SEDs) in SSD or HDD formats Full Disk Encryption (FCE) based on AES-256 Drives certified to FIPS 140-2 Level 2 Key Management Server (KMS) options available for FIPS 140-2 Level 1, 2 and 3 External key manager support Gemalto’s SafeNet KeySecure k460, k250, k170v, k150v Thales EMS 200 |
Features
Unprecedented advantage at this price point
Why should budget constraints limit your access to state-of-the-art storage technology? The new SCv3000 Series arrays pack more advanced capabilities in an entry-level hybrid solution than ever before, helping even the smallest companies compete effectively against larger, more expensive deployments.
SCv3000 starting cost is among the lowest in the industry – but don’t let the price fool you! This array punches well above its weight, offering a unique combination of features designed to accelerate business outcomes for budget-conscious customers.
![]() Great hybrid performance
“0-100% Flash” architecture powers over 270,000 max IOPS, >19,000 MB/sec bandwidth, and 1PB raw capacity per array* – more than enough headroom to handle multiple demanding workloads.
|
![]() Self-optimizing architecture
Automate your cost savings to extract more value from fewer, less expensive drives. Multi-tier Data Progression, RAID tiering and Intelligent Compression actively reduce both initial and lifecycle costs.
|
![]() Future-proof investment
Buy with confidence, knowing SCv3000 has full membership in a broader portfolio that will complement your environment, now and in the future. SC Series federation/replication, robust Dell EMC product support, 3rd-party tie-ins.
|
What’s New?Compared to the previous-generation SCv2000, SCv3000 represents a giant leap forward in capabilities for the SC entry category.
|
![]() |
![]() |
SCv3000 Series ModelsThe base array is available in two 3U “all-in-one” configurations. Both models include dual controllers with 6-core Intel processors, 32GB memory (16GB per controller) and flexible 10Gb iSCSI, 12Gb SAS or 16Gb FC network connections.
|
![]() |
4:1 All-Flash Storage Efficiency GuaranteeSC Series arrays are efficient in ANY configuration (all-flash, hybrid and HDD) – but we know many businesses are especially concerned about expense when deploying all-flash arrays. That’s why we’re taking the risk out of AFAs by guaranteeing 4:1 efficiency for all-flash SC configurations. Dell EMC promises our all-flash arrays will provide an effective logical storage capacity at least four times the physical capacity of your purchased drives – or we’ll give you more drives at no charge.* |

Reviews
There are no reviews yet.